MOXA CN2650I-16-HV-T Terminal Server
- LCD panel for easy IP address configuration (excluding wide-temperature range models)
- Dual-LAN cards with two independent MAC addresses and IP addresses
- Redundant COM function available when both LANs are active
- Dual-host redundancy can be used to add a backup PC to your system
- Dual-AC-power inputs (for AC models only)
- Real COM/TTY drivers for Windows and Linux
- Universal high-voltage range: 100 to 240 VAC or 88 to 300 VDC
- With 2 kV isolation
Description
Redundancy is an important issue for industrial networks, and various types of solutions have been developed to provide alternative network paths when equipment or software failures occur. “Watchdog” hardware is installed to utilize redundant hardware, and a “Token”- switching software mechanism is applied. The CN2600 terminal server uses its built-in Dual-LAN ports to implement a “Redundant COM” mode that keeps your applications running uninterrupted.
Dual-LAN Redundancy
The CN2600 has two separate LAN ports that can be connected
to separate LAN networks. Dual-LAN redundancy involves setting up two separate
physical networks to connect the PC host with the CN2600 (the PC host also
requires two LAN cards). If one connection fails, the PC host can still
communicate with your serial devices over the alternative LAN connection.
You can also find the CN2610-16-2AC and CN2650I-16 models in the
Serial-To-Ethernet Converters.
Explore our extensive range of industrial automation
products such as MOXA CN2650I-16-HV-T Terminal Server in the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh),
and Oman). Submit your inquiry to enjoy
the on-time delivery service. Our sales experts will contact you to fulfill all
your industrial automation needs.
Specification
ETHERNET INTERFACE | |
---|---|
No. of Ports | 2 x 10/100BaseT(X) Ports (RJ45 connector) |
SERIAL INTERFACE | |
Flow Control | RTS/CTS, DTR/DSR, XON/XOFF, None |
No. of Ports | 16 |
Connector | DB9 male |
Serial Standards | RS-232, RS-422, RS-485 |
Operation Modes | Real COM mode, TCP Server mode, TCP Client mode, UDP mode, RFC2217 mode, Terminal mode, Reverse Telnet mode, PPP mode, DRDAS mode, Redundant COM mode, Disabled |
Baudrate | 50 bps to 921.6 kbps |
Data Bits | 5, 6, 7, 8 |
Stop Bits | 1, 1.5, 2 |
Parity | Even, Odd, Space, Mark, None |
POWER PARAMETERS | |
Input Current | 200 mA @ 88 VDC |
Input Voltage | 110 VDC (88 to 300 VDC) |
PHYSICAL CHARACTERISTICS | |
Housing | Metal |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
MTBF | 241,404 hrs |
Standards and Certifications | EMC, EMI, EMS, Safety, Vibration, Freefall, RoHS, CRoHS, WEEE |