  • EX Approved Managed Ethernet Switch
  • Layer 2 functionality switching
  • 4 x 10 Mbit/s, 100 Mbit/s Copper ports (RJ-45 connector)
  • 2 x 100/1000 Mbit/s SFP Ports, Ethernet FX (LC) or TX SFP (RJ-45)
  • IP40-rated Zinc body material design
  • DIN-rail mount installation
  • 24 to 48 VDC Redundant dual inputs (Wide Range 19 to 60 VDC)
  • -40 to +70°C operating temperature range

  • Operating Temperature (-40 to 70°C)
  • Relative Humidity (5% to 95% RH)
  • IP protection (IP40)
  • Shock (IEC 60068-2-27)
  • Vibration (IEC 60068-2-6)
  • Hazardous Location (UL/cUL Class 1 Division 2, ATEX, IECEx)
  • Railway Transportation
  • Marine
  • Oil & Gas
$0.00
Ex Tax: $0.00

The Lynx 106 EX is a layer 2 managed industrial Ethernet switch, powered by the Westermo WeOS network operating. Independently tested for IECEX and ATEX by Baseefa, Lynx is the perfect solution for hazardous area applications worldwide. Lynx is the most compact and has the lowest power requirements in this switch class. Lynx has 8 10/100 Mbit/s ports in addition to 2 ports which can be fitted with Gbit or 100 Mbit SFP transceivers.

Only industrial-grade components are used, which gives the Lynx an MTBF of 615,000 hours and ensures a long service life. A wide operating temperature range –40 to +70°C (–40 to +158°F) can be achieved with no moving parts or cooling holes in the case. Lynx has been tested both by Westermo and external test houses to meet many EMC, isolation, vibration, and shock standards, all to the highest levels suitable for heavy industrial environments and rail trackside applications.


End of Life Product - No Replacement

Please note that the L106-F2G EX has been phased out. You can explore the L106-F2GL105-S1L108-F2G-S2L206-F2G, and L208-F2G-S2 models in the Managed Ethernet Switches.


Inquire about the Westermo L106-F2G EX Managed Ethernet Switch, designed for industrial automation solutions. Feel free to get in touch with our sales team to give you the best solutions at the best global price in the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh), and Oman).

switch and hub : Interface
Number of ports 6 Ports
10/100Mb RJ45 (Megabit) Ports Yes : 4 Ports (or 10 Mbit/s)
10/100/1000Mb RJ45 (Gigabit) Ports No
100Mb Fiber optic multi mode (Megabit) Ports No
100Mb Fiber optic single mode (Megabit) Ports No
100Mb SFP Fiber optic (Megabit) Ports No
1000Mb SFP Fiber optic (Gigabit) Ports Yes : 2 Ports, Ethernet FX (LC) or TX SFP (RJ-45)
10/100Mb (Megabit) POE Ports No
10/100/1000Mb (Gigabit) POE Ports No
Other ports Yes : 1 x USB 2.0 Port, 1 x Digital I/O channel (4-position detachable screw termina), 1 x Console Port (2.5 mm jack)
switch and hub : Features and capabilities
Backup No
switch and hub : LED Indicators
LED Per Port Yes
switch and hub : Power Requirements
Input Current 180 mA (330 mA) @ 24 VDC (with 500 mA USB load), 90 mA (170 mA) @ 48 VDC (with 500 mA USB load)
Power Input Plugin ( Redundant ) Yes
Input Voltage 24 to 48 VDC (with Galvanic isolation to all ports)
Operating Voltage 19 to 60 VDC
Power Consumption -
switch and hub : General
Fan / Fanless Fanless
MTBF MIL-HDBK-217K: 615,000 hours
switch and hub : Switch specifications
Most forwarding speed -
Network working layers Layer 2
Switch type Managed
Port Aggregation Yes
switch and hub : Physical Characteristics
Dimensions 52 x 100 x 101 mm (2.04 x 3.93 x 3.97 in)
Housing Metal
Installation Din-rail mounting
Operating Temperature -40 to +70°C (-40 to +158°F)
Operation Humidity 5-95% relative humidity
Standards and Certifications MIL-HDBK-217K; Ingress protection: IP40; Corrosive gases: IEC 60068-2-60; EMC: EN 61000-6-1, Immunity residential environments, EN 61000-6-2, Immunity industrial environments, EN 61000-6-4, Emission industrial environments, EN 55022 +A1, Emission IT equipment, EN 55024, Immunity IT equipment, FCC part 15 Class A, EN 50121-4, Railway signalling and telecommunications apparatus, IEC 62236-4, Railway signalling and telecommunications apparatus; Safety: UL/IEC/EN 60950-1, IT equipment; Marine: DNV Standard for Certification no. 2.4; IECEx: Explosive atmosphere, IEC 60079-0, General requirements, IEC 60079-15, Equipment protected by type of protection “n”, IEC 60079-28, Protection of equipment and transmission systems using optical radiation; ATEX: Explosive atmosphere, EN 60079-0, General requirements, EN 60079-15, Equipment protected by type of protection “n”, EN 60079-28, Protection of equipment and transmission systems using optical radiation; Class1 Div 2: FM Approval; Shock: IEC 60068-2-27; Vibration: IEC 60068-2-6
Storage Temperature -50 to +85°C (-58 to +185°F)
Weight 0.7Kg
switch and hub : Standards and protocols
Protocols and work standards -
Protocols and management standards IGMPv2/v3, HTTP and HTTPS or CLI (SSHv2 or Telnet), SNMPv1/v2c/v3, SNTP (NTP client), PPPoE client, DHCP client, DHCP server including option 82, DHCP relay agent including option 82, DDNS
switch and hub : Package Checklist
Hardware installation guide Yes
Power adapter No
Power cable No