MOXA ICF-1280I-S-ST PROFIBUS to Fiber converter
- Profibus Converter to Single-Mode Fiber-Optic
- 2 ST fiber optic ports and 1 DB9 female Profibus port
- 2KV Electrostatic Discharge Protection
- Power Input 12V DC to 48V DC
- Brand: MOXA
- Product Code: ICF-1280I-S-ST
Description
The ICF-1280I industrial PROFIBUS-to-fiber converters are used to convert PROFIBUS signals from copper to optical fiber. The converters are used to extend serial transmission up to 4 km (multi-mode fiber) or up to 45 km (single-mode fiber). The ICF-1280I Series provides 2 kV isolation protection for the PROFIBUS system and dual power inputs to ensure that your PROFIBUS device will perform uninterrupted.
You can also find the ICF-1280I-M-ST, ICF-1280I-M-ST-T, and ICF-1280I-S-ST-T models in the Protocol Converters.
You can explore our wide range of
products and enquire about the MOXA ICF-1280I-S-ST PROFIBUS to Fiber converter for your industrial automation needs. Our
sales experts will pave the way to buy at the lowest price in Dubai, UAE, Saudi Arabia, Oman, and the Middle
East.
Specification
Power Requirements | |
---|---|
Input Voltage | 12 to 48 VDC |
Input Current | 315 mA @ 12 VDC |
Connector | Terminal Block |
Power Line Protection | Level 3 (2 kV) Surge Protection |
Overcurrent Protection | 1.1 A |
PROFIBUS Communication | |
Data Rate | 9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, and 12000 Kbps |
Auto Baudrate | |
Isolation Protection | 2 kV |
Interface | |
Relay Alarm | One relay output with current-carrying capacity of 2 A @ 30 VDC (Normal open) |
LED Indicators | PWR1, PWR2, Ready, P1, P2, P3, Fault |
DIP Switches | DIPs 1 to 4: Baudrate setting, DIP 5: Fiber link monitor, DIPs 6 to 7: Linear/Star mode (w/ optional P1/P2 disabled), Redundant Ring mode, DIP 8: Remote Fiber Diagnosis |
P1/P2/P3 Ports | P1/P2 ports: ST optical fiber, P3 port: PROFIBUS DP (DB9 female) |
General | |
MTBF | 1,567,875 hrs |
Physical Characteristics | |
Dimensions | 39 x 115 x 70 mm (1.54 x 4.53 x 2.76 in) |
Housing | Metal |
Operating Temperature | 0 to 60°C (32 to 140°F) |
Storage Temperature | -40 to 75°C (-40 to 167°F) |
Weight | 225 g (0.49 lb) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Safety | UL 508 |
Hazardous Location | UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 EEx nC IIC, IECEx |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | EN 61000-4-2 (ESD): Contact: 6 kV; Air: 8 kV, EN 61000-4-3 (RS): 80 MHz to 1 GHz: 10 V/m, EN 61000-4-4 (EFT): Power: 2 kV; Signal: 2 kV, EN 61000-4-5 (Surge): Power: 2 kV; Signal: 2 kV, EN 61000-4-6 (CS): 150 kHz to 80 MHz: 10 V/m, EN 61000-4-8 (PFMF) |
Green Product | RoHS, CRoHS, WEEE |
Freefall | IEC 60068-2-32 |
Technology Standards | IEC 61158-2 for PROFIBUS DP |
Mounting | DIN rail, wall (with optional kit) |