  • 1 x RS-232/422/485 Serial port (DB9-F for RS-232, TB for RS-422/485)
  • 1 x 100Mbps Fiber optic port (Single-mode ST connector)
  • 40 km Typical data transmission distance on fiber
  • 12 to 48 VDC input power range
  • IP30-rated Metal body design
  • DIN-rail mounting
  • 2 KV Serial isolation protection
  • 0 to 60°C operating temperature

  • Brand: MOXA
  • Model: ICF-1150I-S-ST-IEX
  • Operating Temperature (0 to 60°C)
  • Relative Humidity (5 to 95% non-condensing)
  • Vibration (IEC 60068-2-6)
  • IP protection (IP30)
  • Hazardous Location (UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2, IECEx Zone 2)
  • Oil & Gas
$0.00
Ex Tax: $0.00

The ICF-1150 serial-to-fiber converters transfer RS-232/RS-422/RS-485 signals to optical fiber ports to enhance transmission distance. When an ICF-1150 device receives data from any serial port, it sends the data through the optical fiber ports. These products not only support single-mode and multi-mode fiber for different transmission distances, but models with isolation protection are also available to enhance noise immunity. The ICF-1150 products feature three-way communication and a rotating switch to set the pull high/low resistor for onsite installation.

Three-Way Communication

The ICF-1150 Series supports 2 serial ports, with a DB9 connector for RS-232 communication and a removable terminal block for RS-422 or RS-485 communication. The 3 ports (2 serial ports and one fiber port) are completely independent. When an ICF-1150 converter receives data from any one port, it will send the data through the other 2 ports. For example, once the ICF-1150 converter receives a command from the remote master through the fiber port, it will convert the signal and send the command through the RS-232 and RS-422/485 ports at the same time. If the user is monitoring a system running on an RS-485 network, there is no need to use an additional RS-232 to RS-485 converter to connect the laptop computer’s serial port to the RS-485 bus.

Rotary Switch for Setting the Pull High/Low Resistor

The RS-485 interface supports multidrop or daisy-chain connections, which system engineers will use to connect serial devices such as meters, RTUs, and readers, together on the same bus. Since the number of serial devices on the same bus will cause the impedance of the data line to increase, the ICF-1150 allows users to tune the pull high/low resistor. Just rotate the switch to the appropriate value without removing the ICF-1150 from the DIN rail.

 

You can also find the ICF-1150I-S-ST-T-IEX and ICF-1150-S-ST-IEX models in the Industrial Media Converters.

 

Easy World Automation offers the easiest way to buy the MOXA ICF-1150I-S-ST-IEX Serial to Fiber Converter in the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh), and Oman) at the lowest price through online inquiring. Our sales experts will contact you to fulfill all your industrial automation needs.

converter : Interface
100Mb Fiber optic single mode (Megabit) PortsYes : 1 ST Port
100Mb Fiber optic multi mode (Megabit) PortsNo
Serial portYes : 1 x RS-232/422/485 Port (DB9-F for RS-232, TB for RS-422/485)
USBNo
Other portsNo
IsolationYes : 2KV
converter : Converter specifications
Data transfer speed ( Baudrate )0.05Kbps to 921.6Kbps
Maximum data transmission distance40Km on the fiber
Minimum output power converter-8dBm
Sensitivity to receiving information-25dBm
Wavelength1310nm
Require cable diameterG.652
Flow ControlADDC (automatic data direction control) for RS-485
Protocols-
converter : Serial Signals
RS-232 SignalsTxD, RxD, GND
RS-422 SignalsTxD+, TxD-, RxD+, RxD-, GND
RS-485-2w SignalsData+, Data-, GND
RS-485-4w SignalsTx+, Tx-, Rx+, Rx-, GND
converter : Power Requirements
Power Consumption (Output Adapter)300 mA @ 12 to 48 VDC
Power Input Plugin ( Redundant )No
Overload Current ProtectionSupported
Reverse Polarity ProtectionSupported
Input Voltage12 to 48 VDC
Input Current300 mA @ 12 to 48 VDC
ConnectorTerminal block
converter : General
Fan / FanlessFanless
MTBF792,085 hour
converter : Physical Characteristics
Dimensions30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in)
HousingMetal
InstallationDIN-rail mounting
Operating Temperature0 to 60°C (32 to 140°F)
Operation Humidity5% to %95 non-condensing
Standards and CertificationsEMC: EN 55032/35; EMI: CISPR 32, FCC Part 15B Class A; EMS: IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m, IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV, IEC 61000-4-5 Surge: Power: 4 kV; Signal: 1 kV, IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m, IEC 61000-4-8 PFMF; Environmental Testing: IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-3; Safety: UL 61010-2-201; Vibration: IEC 60068-2-6; Hazardous Locations: UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2, IECEx; IP30; Telcordia (Bellcore), GB
Storage Temperature-40 to 85°C (-40 to 185°F)
Weight330 g (0.73 lb)
converter : LED Indicators
LED Per PortNo
PowerYes

Write a review