Your Cart

MOXA 65M-BMCPU01-CT-T Backplane Module

MOXA 65M-BMCPU01-CT-T Backplane Module
MOXA 65M-BMCPU01-CT-T Backplane Module
Key Features:
  • Backplane module for modular programmable IIN controllers
  • 1 x Slot for CPU module
  • Plastic housing design
  • DIN-rail and rack mounting 
  • -40 to 75°C operating temperature
  • Brand: MOXA
  • Model: 65M-BMCPU01-CT-T
  • Operating Temperature (-40 to 75°C)
  • Relative Humidity (5 to 95% non-condensing)
  • Shock (15g, half-sine, 11ms according to IEC60068-2-27)
  • Vibration (IEC 60068-2-6)
$0.00
Ex Tax: $0.00

The ioPAC 6500 Series (also referred to as Intelligent Integrated Node or IIN) is an advanced Linux-based RTU featuring a built-in Layer-2 managed switch. Equipped with an Arm Cortex-A53 quad-core CPU, the ioPAC 6500 Series delivers robust performance.

You can also find the 65M-BMCM01-CT-T, 65M-BMCPU02-CT-T, and 65M-BMEXP01-CT-T models in the MOXA ioPAC 6500 Series (65M) Backplane Modules.

Inquire about the MOXA 65M-BMCPU01-CT-T Backplane Module, designed for industrial automation solutions. Feel free to get in touch with our sales team to give you the best solutions at the best global price in the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh), and Oman).

REMOTE I/O MODULES : INPUT/OUTPUT INTERFACE
Digital Input and Output No
Analog Input and Output No
System Power Input Channels No
Thermocouple Channels No
Field Power Input and Output No
Relays No
RTD Channels No
Ethernet Ports No
CAN Ports No
Serial Ports No
Isolation No
REMOTE I/O MODULES : SERIAL INTERFACE
Connector -
Serial Standards -
Serial Communication Parameters -
Serial Signals -
REMOTE I/O MODULES : GENERAL
MTBF 5,032,783,357 hrs
REMOTE I/O MODULES : POWER REQUIREMENTS
Power Connector -
Input Voltage -
Power Consumption -
REMOTE I/O MODULES : PHYSICAL CHARACTERISTICS
Housing Plastic
Dimensions 43 x 177 x 45.5 mm (1.69 x 6.97 x 1.79 in)
Installation DIN-rail mounting, Rack mounting (with optional kit)
Storage Temperature -40 to 85°C (-40 to 185°F)
Weight 170 g (0.37 lb)
Ambient Relative Humidity 5 to 95% (non-condensing)
Operating Temperature -40 to 75°C (-40 to 167°F), Note: Proper airflow is required in an environment with temperature > 65°C
Standards and Certifications EMC: EN 55032/35, EN 61000-6-2/-6-4; EMI: CISPR 32, FCC Part 15B Class A; EMS: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m, IEC 61000-4-4 EFT: Power: (DC) 1 kV; Signal: 1 kV, IEC 61000-4-5 Surge: Power: (DC) 0.5 kV L-N, 1 kV L/N-PE; Signal: 1 kV; IO: 0.5 kV, IEC 61000-4-6 CS: Power: 10 V; Signal: 10 Vrms, IEC 61000-4-8 PFMF: 30 A/m; Safety: UL 61010-1, UL 61010-2-201; Shock: IEC 60068-2-27, Half sine wave; acceleration: 15 g; time: 11 ms; Vibration: IEC 60068-2-6; DIN-rail mounted: 7 mm peak-peak (p-p) (2 to 8.42 Hz), 1 g (8.42 to 150 Hz); Rack mounted (with optional kit): 7 mm peak-peak (p-p) (2 to 8.42 Hz), 0.5 g (8.42 to 150 Hz); Package Vibration Test: ISTA 1A; Package Drop Test: ISTA 1A; Telcordia Standard SR-332
Altitude 2000 m

Write a review

Note: HTML is not translated!
Rating
Bad Good
Captcha