Description
Quasi-Wide-Range Input: With the switch in the 230V position the power supply unit operates at low and moderate loads (until 3 A) at any input voltage between 95 and 264 V AC. Note: At DC input, always leave the switch in the 230V position.
To be fused with a 10A, B-type 'circuit-breaker' switch based on the usual thermomagn. overload sensing principle (used anyway to fuse the input lines). In addition, the unit contains an internal fuse (not accessible).
You can place an order for the PULS SLR5.100 Power supply online via one of our Middle East branches (Dubai/ Oman/Saudi Arabia) and get it delivered at a low cost at a specific time.
Specification
Input Data | |
---|---|
AC-Input Voltage | AC 100-120/210-240V |
DC-Input Voltage | - |
EN61000-3-2(PFC-Norm) | fulfilled |
Output Data | |
nominal Voltage | 24Vdc |
Adjustment Range | 24 |
Output Current Range | 5A |
Output Current | 5A at 24V |
Output Power | 120W |
max. Ripple and Noise Voltage | 30mVpp |
Physical Characteristics | |
Dimension | 64mm x 124mm x 102mm |
Weight | 620g |
Mounting | DIN-Rail |
Operating Temperature | -10°C ... +70°C |
General | |
Derating | 3W/° at >+61°C |
Efficency, typ. | 89,0% |
Power Losses, typ. | 14,8W |
MTBF | 480.000h |
Connection method | plug connector |
E Classification | eClass 5.1 27049002, eClass 6.x 27049002, eClass 7.x 27049002, eClass 8.0 27049002, eClass 9.0 27040701, ETIM 4.0 EC000599, ETIM 5.0 EC002540, HS Code HS 85044082 |
Package Checklist | |
Packaging Unit | 1pc |