MOXA TN-4908-ETBN-F-4TXBP-WV-CT-T Industrial Secure Router
- 4 x 10/100BaseT(X) Ports (M12 connector)
- 4 x 10/100BaseT(X) Ports (M12 connector with bypass relay)
- IP40-rated Metal body design
- 24 to 110 VDC Redundant dual power inputs
- Wallmount installation design
- Supports IEC 61375 ETBN functionality and Firewall
- -40 to 70°C operating temperature
Description
The ToughNet TN-4900 Series, designed for rolling stock
Ethernet networks, is a set of high-performance M12 routers with 8 Gigabit
ports and up to four bypass relay ports. These routers feature firewalls, ETBN,
and routing functionality to facilitate the deployment of applications across
networks. The TN-4900 Series routers use M12 and other circular connectors to
ensure tight, robust connections that guarantee reliability against
environmental disturbances, such as vibration and shock.
The TN-4900 Series supports a wide power input range of 24
to 110 VDC and can operate in temperatures of -40 to 70°C for extended periods
of time. Furthermore, these routers are compliant with the mandatory
requirements of EN 50155, making them suitable for a variety of industrial
applications.
You can also find the TN-4908-ETBN-F-4GTX-4GTXBP-WV-CT-T, TN-4908-ETBN-F-4GPoE-4GTXBP-WV-CT-T, and TN-4908-ETBN-4GTXBP-WV-CT-T models in the Industrial Secure Routers.
Explore our extensive range of industrial automation
products such as MOXA TN-4908-ETBN-F-4TXBP-WV-CT-T Industrial Secure Router in
the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh), and Oman). Submit your inquiry to enjoy the on-time
delivery service. Our sales experts will contact you to fulfill all your
industrial automation needs.
Specification
INTERFACE | |
---|---|
Ethernet Ports | 4 x 10/100BaseT(X) Ports (M12 D-coded 4-pin female connector), 4 x 10/100BaseT(X) Ports (M12 D-coded 4-pin female connector with bypass relay) |
Serial Ports | 1 x Console Port: RS-232 (M12 B-coded 5-pin female connector) |
Input/Output Channels | |
Alarm Contact Channels | |
SOFTWARE SPECIFICATIONS | |
Management | Back Pressure Flow Control, SNMP Inform, LLDP, Syslog, HTTP, HTTPS, Flow control, SMTP, QoS/CoS/ToS, Port Mirror, SNMP, Trap, SNMPv1/v2c/v3, IPv4, Telnet, DHCP Server, SFTP, SCP, TFTP, RARP, Account Management, DHCP Client (Option 1/3/12/50/51/53/54/55/57/61/66/67/124/255), DHCP Server (Option 1/3/6/12/15/28/42/50/55), DHCP Relay Agent |
Routing Redundancy | VRRP |
Security | Secure Boot, IPsec, L2TP (server), RADIUS, Trust access control |
Time Management | SNTP, NTP Server/Client |
Encryption | 3DES, DES, AES-128, AES-192, AES-256 |
Authentication | MD5 and SHA (SHA-256), RSA (key size: 1024-bit, 2048-bit), X.509 v3 certificate |
LED INTERFACE | |
LED Indicators | STATE, PWR1, PWR2, FAULT, 10/100/1000M, PoE |
GENERAL | |
Supported Protocols | RSTP, Static Port Trunk, Turbo Ring v2, STP, Ethernet protocols, DNP, DPI, EtherCAT, EtherNet/IP, FOUNDATION Fieldbus, FTP, HTTP, IEC 60870-104, IPsec, L2TP, LonWorks, Modbus TCP, PPTP, PROFINET, RADIUS, SSH, Telnet, VPN |
MTBF | 648,903 hrs |
POWER REQUIREMENTS | |
Input Voltage | 24/36/48/72/96/110 VDC, Redundant dual inputs |
Input Current | 0.65 A @ 24 V |
Operating Voltage | 16.8 to 137.5 VDC |
Overload Current Protection | |
Reverse Polarity Protection | Supported |
Power Connector | M12 K-coded 5-pin male connector |
PHYSICAL CHARACTERISTICS | |
Housing | Metal |
Dimensions | 160 x 115 x 70 mm (6.30 x 4.53 x 2.76 in) |
Weight | 1120 g (2.47 lb) |
Installation | Wall mounting |
Operating Temperature | -40 to 70°C (-40 to 158°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Standards and Certifications | EMC: EN 55032, EN 55035; EMI: CISPR 32, FCC Part 15B Class A; EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m, IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV, IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV, IEC 61000-4-6 CS: 10 V, IEC 61000-4-8 PFMF; Radio Frequency: FCC; Railway: EN 50121-4, EN 50155, IEC 60068-2-1, EN 50155, IEC 60068-2-14, EN 50155, IEC 60068-2-2, EN 50155, IEC 60068-2-30, EN 50155, IEC 60068-2-78, IEC 60571; Railway Fire Protection: EN 45545-2; Safety: IEC 62368, UL 62368; Salt Spray Test: EN 50155; Shock: IEC 60068-2-27, IEC 61373, EN 50155; Vibration: IEC 60068-2-64, IEC 61373, EN 50155; Package Drop: Test ISTA 1A; IP40; Green Product: RoHS, CRoHS, WEEE; Telcordia SR332 Issue 2 |