MOXA NDR-120-24 DIN-rail Power Supply | Easy World Automation

MOXA NDR-120-24 DIN-rail Power Supply

  • 90 to 264 VAC, 127 to 370 VDC Input power range
  • 24 VDC (120 W) Output power range
  • Metal body design
  • DIN-rail mounting
  • -20 to 65°C operating temperature range

Description

The NDR Series of DIN rail power supplies is designed specifically for use in industrial applications. The 40 to 63 mm slim form factor enables the power supplies to be easily installed in small and confined spaces such as cabinets. The broad operating temperature range of -20 to 70°C means they are capable of operating in harsh environments. The devices have a metal housing, an AC input range from 90 VAC to 264 VAC, and conform to the EN 61000-3-2 standard. In addition, these power supplies feature a constant current mode to provide overload protection.


You can also find the NDR-120-48 and NDR-240-48 models in the Power supplies.


Explore our extensive range of industrial automation products such as MOXA NDR-120-24 DIN-rail Power Supply in the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh), and Oman).  Submit your inquiry to enjoy the on-time delivery service. Our sales experts will contact you to fulfill all your industrial automation needs.

Specification

Power Requirements
Input Voltage: 90 to 264 VAC (47 to 63 Hz) or 127 to 370 VDC; Typical Current: 1.3 A @ 230 VAC, 2.25 A @ 115 VAC; Inrush Current (cold start): 35 A @ 230 VAC, 20 A @ 115 VAC
Operating Voltage -
Output Wattage: 120 W; Voltage: 24 VDC; Current Rating: 0 to 5 A
Over-voltage Protection 29 to 33 V (Shut down operating voltage, repower on to recover)
Overload Protection 105 to 160% (Constant current limiting, recovers automatically after fault condition is removed)
Reverse Polarity Protection -
Physical Characteristics
Dimensions 123.75 x 125.20 x 40 mm (4.87 x 4.93 x 1.57 in)
Housing Metal
Weight 500 g (1.10 lb)
Ambient Relative Humidity 20 to 95% (non-condensing)
Operating Temperature -20 to 70°C (-4 to 158°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Installation DIN-rail mounting
Standards and Certifications Safety: UL 508, EN 62368-1, IEC 62368-1; EMC: EN 55032/35, EN 61000-3-2 Class A, EN 61000-3-3, EN IEC 61204-3, EN IEC 61000-6-2; EMS: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 , Hz to 1 GHz: 10 V/m, IEC 61000-4-4 EFT: Power: 2 kV, IEC 61000-4-5 Surge: Power: 4 kV, IEC 61000-4-6 CS: 0.15 kHz to 80 MHz: 10 Vrms, IEC 61000-4-8: 30 A/m, IEC 61000-4-11; MIL-HDBK-217F
MTBF 453,334 hrs
Supported Series