MOXA PTC-101-M-LC-HV Ethernet To Fiber Converter | Easy World Automation

MOXA PTC-101-M-LC-HV Ethernet To Fiber Converter

  • 1 x 10/100Mbps T(x) port and 1 x 100Mbps F(x) multi-mode port with LC connector
  • 20 to 72 VDC input power
  • Metal body
  • -40 to 85°C operating temperature

Description

The PTC-101 Ethernet-to-fiber media converters convert from 10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or LC connectors. The PTC-101 converters eliminate the need for additional wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for your industrial Ethernet networks. The PTC-101 is compliant with mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD, and vibration, as well as conformal coating and power insulation, making the switches suitable for a variety of industrial applications.

 

You can also find the PTC-101-M-ST-LV, PTC-101-M-ST-HV, PTC-101-M-SC-LV, and PTC-101-M-SC-HV models in the Industrial Media Converters.

 

Inquire about the MOXA PTC-101-M-LC-HV Ethernet To Fiber Converter, designed for industrial automation solutions. Feel free to get in touch with our sales team to give you the best solutions at the best global price in the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh), and Oman).

Specification

Interface
10/100BaseT(X) Ports 1
100BaseFX Ports 1 x Multi-mode LC
Magnetic Isolation Protection 1.5 kV (built-in)
General
MTBF 4,660,534 hrs
Power Requirements
Input Voltage 100 to 240 VAC, 100 to 240 VDC
Input Current 350 to 200 mA @ 100 to 240 VAC, 350 to 200 mA @ 100 to 240 VDC
Overload Current Protection Supported
Power Consumption 350 to 200 mA @ 100 to 240 VAC, 350 to 200 mA @ 100 to 240 VDC
Physical Characteristics
Housing Metal
Dimensions 152.15 x 126.46 x 66.65 mm (5.99 x 4.86 x 2.62 in)
Weight Packaged: 952 g (2.09 lb), Product only: 785 g (1.73 lb)
Operating Temperature -40 to 85°C (-40 to 185°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
EMC EN 55032/35
Operation Humidity 5 to 95% (non-condensing)
EMI CISPR 32, FCC Part 15B Class A
Installation DIN-rail mounting
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m, IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV, IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV, IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m, IEC 61000-4-8 PFMF, IEC 61000-4-11
Safety EN 62368-1, UL 62368-1, UL 60950-1
Vibration IEC 60068-2-6