Westermo Ibex-RT-220-LV EU Client/Bridge/Access Point
- Supports Europe Frequency Bands
- Configurable as Access Point, Client, or Bridge
- 2 x 10/100 Base-T Ethernet ports (M12 connector)
- 24 VDC isolated or IEEE 802.3 at type 1 powered device
- IP66-rated Metal body design
- -40 to +70°C operating temperature range
Description
The Westermo Ibex-RT-220 is a Wireless LAN Node for on-board
and stationary applications. It ensures reliable connection for applications
such as video transmission and TCMS, especially useful for transparent
inter-consist links (ICL) with automatic reconfiguration. The Ibex-RT-220,
along with the application-specific ICL antenna, is designed to withstand the
tough environment on-board trains, exposing equipment to constant vibration,
extreme temperatures, humidity, and a demanding electromagnetic environment.
The radio module is calibrated to ensure high RF sensitivity
(even at high data rates/modulations), stable RF links, optimized DFS handling,
etc. A GORE-TEX® membrane prevents internal condensation. High-level isolation
between all interfaces enables direct connectivity to vehicle auxiliary power
and protects against overvoltage and spikes/surges (powering over PoE is also
available). IP66 protection prevents water and dust ingress even at the
quick-connect QMA connectors. An overall optimized design results in a compact
form factor in combination with very high MTBF for easy integration in space-restricted & outdoor installations and low lifecycle cost.
Thorough type testing at independent labs certifies compliance to a wide range of standards, not least EN 50155, FCC, and EN 300440
(the latter opens the possibility to use the 5.8 GHz band in the EU region).
Meeting the requirements of the railcar market, the RT-220 is very well suited
for deployment in any other application with severe operating conditions and
tough environments, for instance in the mining or shipping industry.
You can also find the Ibex-RT-220-LV NA, Ibex-RT-220-HV EU,
and Ibex-RT-220-HV NA models in the WLAN.
Experience the convenient way to purchase the Westermo Ibex-RT-220-LV EU Client/Bridge/Access Point in the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh), and Oman). Our sales experts will provide the most helpful information about the price and sale conditions for a wonderful buying experience.
Specification
Interfaces | |
---|---|
10/100/1000BaseT(X) Ports | |
Modulation Type | - |
Frequency Band | 2.400 to 2.4835 GHz, 5.150 to 5.350 GHz, 5.470 to 5.725 GHz, 5.725 to 5.875 GHz |
PoE Ports | |
100BaseFX Ports | |
Wireless Security | WPA2 (CCMP), WPA3-Personal (SAE/OWE), WPA3-Enterprise (Suite-B), 802.11w, 802.1X, 802.11r |
WLAN Antenna Connector | 2 x QMA compatible antenna connectors, 2x2 MIMO |
Security | SSL VPN (Client and Server), Certificate Authentication, Pre-shared Key (PSK) Point-to-Point Mode, Layer-2 and Layer-3 VPN, Layer-2 VPN bridging, Generic Routing Encapsulation (GRE) |
WLAN Operation Mode | Access Point, Client, Bridge, Inter-consist Link |
WLAN Standards | IEEE 802.11b, 802.11g, 802.11a, 802.11n |
1000BaseSFP Slots | |
Transmission Rates | 802.11b: 1 Mbit/s, 2, 5.5 and 11 Mbit/s, 802.11g and 802.11a: 6 Mbit/s, 9, 12, 18, 24, 36, 48 and 54 Mbit/s, 802.11n 20 MHz BW, LGI/SGI: from MCS0 6.5/7.2 Mbit/s to MCS15 130/144.4 Mbit/s, 802.11n 40 MHz BW, LGI/SGI: from MCS0 13.5/15 Mbit/s to MCS15 270/300 Mbit/s |
10/100BaseT(X) Ports | : 2 x 10/100 Base-T with 2 x M12 D-codec connectors |
Digital Inputs | |
Console Port | |
Serial Ports | |
M12 Connector | |
Power Requirement | |
Input Current | - |
Connector | - |
Input Voltage | 24 VDC isolated, 0.6 A max. or IEEE 802.3 at type 1 powered device |
Power Consumption | - |
Reverse Polarity Protection | - |
Physical Characteristics | |
Humidity | - |
Dimensions Packaged | 176 x 52 x 110 mm (6.93 x 2.05 x 4.33 inches) |
Weight (PACKAGED) | 1.1 kg without antennas |
Housing | Full metal |
Installation | - |
Standards and Certifications | Ingress protection: IP66; IEC 62380; Climate: EN 50155, class OT4 Railway applications - Electronic equipment used on rolling stock, EN 50125-3, Railway applications – Environmental conditions for equipment, Part 3: Equipment for signalling and telecommunications; EMC: EN 50155, Railway applications - Electronic equipment used on rolling stock, EBA EMV 06, German Federal Railway Authority, Radio compatibility of rail vehicles, EN 50121-3-2, Railway applications – Electromagnetic compatibility, Part 3-2: Rolling stock – Apparatus, EN 50121-4, Railway applications - Electromagnetic compatibility. Part 4: Emission and immunity of the signalling and telecommunications apparatus, ETSI EN 301 489-1, Electromagnetic compatibility (EMC) and Radio spectrum Matters (ERM) for radio equipment and services - Part 1: Common technical requirements, ETSI EN 301 489-17, Electromagnetic compatibility (EMC) and Radio spectrum Matters (ERM) for radio equipment - Part 17: Specific conditions for Broadband Data Transmission Systems, ECE E-Mark, Road Vehicles, E13 10R-06 15771; Mechanical (Shock and vibration): EN 61373, category 1, class A and B, EN 50125-3, Outside the track; Insulation (Coordination and test): EN 50124-1, Railway applications – Insulation coordination, EN 50155, Railway applications - Electronic equipment used on rolling stock; Radio communication: ETSI EN 300 328, Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques, ETSI EN 301 893, 5 GHz RLAN, IEEE 802.11, Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications, FCC-47-15, Radio frequency devices; Safety: EN/IEC 62368-1, Safety Requirements for audio/video, information and communication technology equipment, EN 45545-2, Fire protection on railway vehicles, NFPA 130, Fire protection for fixed guideway transit and passenger rail system |
Operating Temperature | -40 to +70°C (-40 to +158°F) |
Storage Temperature | - |
General | |
Management | SNMP, HTTP/HTTPS with user authentication, CLI (SSH and Telnet) |
LED Indicators | - |
MTBF | 400,000 hours (IEC 62380) |
Time Management | - |