Description
The TCF-142-RM Series slide-in modules are serial-to-fiber
converters that work with the TRC-190 chassis. The modules convert from the
RS-232, RS-422, or RS-485 signal to a fiber-optic signal.
Automatic Baudrate Detection
The TCF-142-RM Series can automatically detect the serial baud rate. This is an extremely convenient feature. Even if a device’s baud rate is changed, the signal will still be transmitted through the media converter without any problem.
You can also find the TCF-142-M-ST-RM, TCF-142-S-ST-RM, and
TCF-142-S-SC-T models in the Industrial Media Converters.
Discover industrial automation solutions appropriate to your
needs, and easily inquire about the NAME through our user-friendly website via
one of our Middle East branches (UAE (Dubai), KSA (Al Khobar, Riyadh), and
Oman).
Specification
| Interface | |
|---|---|
| 100Mb Fiber optic single mode (Megabit) Ports | |
| 100Mb Fiber optic multi mode (Megabit) Ports | : 1 SC Port |
| Serial port | : 2 x RS-232/422/485 |
| USB | |
| Other ports | |
| Isolation | |
| Converter specifications | |
| Data transfer speed ( Baudrate ) | 50 bps to 921.6 kbps (supports non-standard baudrates) |
| Maximum data transmission distance | 5Km on fiber |
| Minimum output power converter | -5dBm |
| Sensitivity to receiving information | -20dBm |
| Wavelength | 850 nm |
| Require cable diameter | 50/125 µm, 800 MHz, 62.5/125 µm, 500 MHz |
| Flow Control | ADDC® (automatic data direction control) for RS-485 |
| Protocols | - |
| Serial Signals | |
| RS-232 Signals | TxD, RxD, GND |
| RS-422 Signals | Tx+, Tx-, Rx+, Rx-, GND |
| RS-485-2w Signals | Data+, Data-, GND |
| RS-485-4w Signals | Tx+, Tx-, Rx+, Rx-, GND |
| Power Requirements | |
| Power Consumption (Output Adapter) | 150 mA @ 12 VDC |
| Power Input Plugin ( Redundant ) | |
| Overload Current Protection | Supported |
| Reverse Polarity Protection | |
| Input Voltage | - |
| Input Current | 150 mA @ 12 VDC |
| Connector | Terminal block |
| General | |
| Fan / Fanless | - |
| MTBF | 514,926 hrs |
| Physical Characteristics | |
| Dimensions | 86.8 x 136.5 x 21 mm (3.42 x 5.37 x 0.83 in) |
| Housing | Metal |
| Installation | - |
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Operation Humidity | 5 to 95% (non-condensing) |
| Standards and Certifications | EMC: EN 55032/24; EMI: CISPR 32, FCC Part 15B Class A; EMS: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m, IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV, IEC 61000-4-5 Surge: Power: 1 kV; Signal: 0.5 kV, IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m, IEC 61000-4-8 PFMF; Environmental Testing: IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-3; Safety: EN 60950-1, IEC 60950-1; Vibration: IEC 60068-2-6 |
| Storage Temperature | -20 to 75°C (-4 to 167°F) |
| Weight | 105 g (0.23 lb) |
| LED Indicators | |
| LED Per Port | |
| Power | |