Description
The goal of zero-latency roaming is to allow clients to
seamlessly maintain their connection as they move from one access point to
another. Moxa's WAC-2004A Industrial Wireless Access Controller features
Controller-based Turbo Roaming technology to enable millisecond-level roaming
across different IP subnets. The advanced roaming algorithm along with Mobile
IP technology allows wireless clients to roam between APs in different IP
subnets within milliseconds while upholding stringent security in extremely demanding
environments. The rugged WAC-2004A is capable of operating at temperatures of 0
to 50°C and is suitable for on-site installation in harsh industrial
environments.
You can also find the WAC-2004 model in the Rail Wireless Access Controller.
Explore our extensive range of industrial automation
products such as MOXA WAC-2004A Wireless Access Controller in the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh),
and Oman). Submit your inquiry to enjoy
the on-time delivery service. Our sales experts will contact you to fulfill all
your industrial automation needs.
Specification
Interfaces | |
---|---|
10/100/1000BaseT(X) Ports | 2 Ports, Port 1: Communications port for WAC/HA, Port 2: Reserved |
PoE Ports | |
Wireless Security | IEEE 802.11i-compliant |
Security | HTTPS/SSL, RADIUS, SSH |
WLAN Operation Mode | Wireless Access Controller |
WLAN Standards | IEEE 802.11i |
Transmission Rates | - |
Digital Inputs | |
Console Port | RS-232 ports x 1 (DB9 male) |
Power Requirement | |
Input Current | 1.2 A @ 100 VAC |
Input Voltage | 100 to 240 VAC |
Power Consumption | - |
Reverse Polarity Protection | |
Physical Characteristics | |
Dimensions Packaged | 304 x 440 x 44 mm (11.97 x 17.32 x 1.73 in) |
EMC | EN 55032/35, EN 61000-6-2/-6-4 |
EMI | CISPR 32, FCC Part 15B Class A |
Weight (PACKAGED) | 4,550 g (10.03 lb) |
Housing | Metal |
Installation | 19-inch rack mounting |
Standards and Certifications | IEEE 802.1X for authentication, IEEE 802.3 for 10BaseT, IEEE 802.3ab for 1000BaseT(X) |
Operating Temperature | 0 to 50°C (32 to 122°F) |
Safety | IEC 60950-1, UL 62368-1, IEC 62368-1 |
General | |
MTBF | 383,478 hrs |