MOXA PTC-101-S-LC-HV Ethernet To Fiber Converter
- Industrial 10/100BaseT(X) to 100BaseFX media converter, single-mode with LC connector
- 1 isolated power supply (88 to 300 VDC or 85 to 264 VAC)
- Input Voltage: 85-264 VAC or 88-300 VDC
- Single-mode LC Fiber Module Type
- Metal body
- -40 to 85°C operating temperature
Description
The PTC-101 Ethernet-to-fiber media converters convert from
10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or LC
connectors. The PTC-101 converters eliminate the need for additional wiring,
and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M,
full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for
your industrial Ethernet networks. The PTC-101 is compliant with mandatory
sections of IEC 61850-3, covering operating temperature, power input voltage, surge,
ESD, and vibration, as well as conformal coating and power insulation, making
the media converters suitable for a variety of industrial applications.
You can also find the PTC-101-S-LC-LV, PTC-101-S-SC-HV, and PTC-101-M-LC-HV models in the Industrial Media Converters.
Discover industrial automation solutions appropriate to your
needs, and easily inquire about the MOXA PTC-101-S-LC-HV Ethernet To Fiber Converter through our user-friendly website via
one of our Middle East branches (UAE (Dubai), KSA (Al Khobar, Riyadh), and
Oman).
Specification
Interface | |
---|---|
10/100BaseT(X) Ports | 1 |
100BaseFX Ports | 1 x single-mode LC connector |
Magnetic Isolation Protection | 1.5 kV (built-in) |
General | |
MTBF | 4,660,534 hrs |
Power Requirements | |
Input Voltage | 100 to 240 VAC, 100 to 240 VDC |
Input Current | 350 to 200 mA @ 100 to 240 VAC, 350 to 200 mA @ 100 to 240 VDC |
Overload Current Protection | Supported |
Power Consumption | 350 to 200 mA @ 100 to 240 VAC, 350 to 200 mA @ 100 to 240 VDC |
Physical Characteristics | |
Housing | Metal |
Dimensions | 152.15 x 126.46 x 66.65 mm (5.99 x 4.86 x 2.62 in) |
Weight | Packaged: 952 g (2.09 lb), Product only: 785 g (1.73 lb) |
Operating Temperature | -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
EMC | EN 55032/35 |
Operation Humidity | 5 to 95% (non-condensing) |
EMI | CISPR 32, FCC Part 15B Class A |
Installation | DIN-rail mounting |
EMS | IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m, IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV, IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV, IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m, IEC 61000-4-8 PFMF, IEC 61000-4-11 |
Safety | EN 62368-1, UL 62368-1, UL 60950-1 |
Vibration | IEC 60068-2-6 |