MOXA PTC-101-S-LC-LV Ethernet To Fiber Converter
- 1 x 10/100BaseT(X) to 100BaseFX media converter, single-mode with LC connector, dual redundant power inputs (20 to 70 VDC)
- Input Voltage: 20-72 VDC
- Single-mode LC Fiber Module Type
- Metal body
- -40 to 85°C operating temperature
- Product Code: PTC-101-S-LC-LV
Description
The PTC-101 Ethernet-to-fiber media converters convert from
10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or LC
connectors. The PTC-101 converters eliminate the need for additional wiring,
and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M,
full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for
your industrial Ethernet networks. The PTC-101 is compliant with mandatory
sections of IEC 61850-3, covering operating temperature, power input voltage, surge,
ESD, and vibration, as well as conformal coating and power insulation, making
the media converters suitable for a variety of industrial applications.
You can also find the PTC-101-S-LC-HV, PTC-101-S-SC-LV, and PTC-101-S-ST-LV models in the Industrial Media Converters.
You can explore our wide range of products and enquire about
the MOXA PTC-101-S-LC-LV Ethernet To Fiber Converter for your industrial automation needs. Our sales experts will pave the
way to buy at the lowest price in Dubai, UAE, Saudi Arabia, Oman, and the
Middle East.
Specification
Interface | |
---|---|
10/100BaseT(X) Ports | 1 |
100BaseFX Ports | 1 x single-mode LC connector |
Magnetic Isolation Protection | 1.5 kV (built-in) |
General | |
MTBF | 4,660,534 hrs |
Power Requirements | |
Input Voltage | 20 to 72 VDC |
Input Current | 150 mA @ 20 VDC |
Overload Current Protection | Supported |
Power Consumption | 150 mA @ 20 VDC |
Physical Characteristics | |
Housing | Metal |
Dimensions | 152.15 x 126.46 x 66.65 mm (5.99 x 4.86 x 2.62 in) |
Weight | Packaged: 952 g (2.09 lb), Product only: 785 g (1.73 lb) |
Operating Temperature | -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
EMC | EN 55032/35 |
Operation Humidity | 5 to 95% (non-condensing) |
EMI | CISPR 32, FCC Part 15B Class A |
Installation | DIN-rail mounting |
EMS | IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m, IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV, IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV, IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m, IEC 61000-4-8 PFMF, IEC 61000-4-11 |
Safety | EN 62368-1, UL 62368-1, UL 60950-1 |
Vibration | IEC 60068-2-6 |