Westermo Ibex-1310-T2G2.5 NA Industrial Wi-Fi 6 Access Point | Easy World Automation

Westermo Ibex-1310-T2G2.5 NA Industrial Wi-Fi 6 Access Point

  • Supports North America Frequency Bands
  • Dual Wi-Fi 6 802.11ax WLAN interfaces
  • 2 x 10/100/1000/2.5G Base-T Ethernet ports (M12 connector)
  • IEEE 802.11ax support for maximum efficiency
  • 9.6 to 60 VDC isolated power supply
  • IP66-rated Metal body design
  • -40 to +70°C operating temperature range

Description

The Ibex-1310 is a concurrent dual-band 802.11ax WLAN access point and client product for industrial vehicle and stationary applications. Ibex-1310 provides reliable efficient high-speed data transfers with the latest cyber security features. The Ibex-1310 is designed to withstand tough environments, exposed to constant vibration, extreme temperatures, humidity, and demanding electromagnetic environments. It is also approved for use in vehicles, such as buses.

A GORE-TEX® membrane prevents internal condensation. High-level isolation between all interfaces enables direct connectivity to vehicle auxiliary power and protects against overvoltage and spikes/surges. IP66 protection prevents the ingress of water. N-type connectors provide industry industry-standard interface to external antennas.

An overall optimized design results in a compact form factor in combination with very high MTBF for easy integration in space-restricted installations and low lifecycle cost. Thorough type testing at independent labs certifies compliance with a wide range of standards, including EN 50121-4. Ibex-1310 is running Westermo's robust and easy-to-use SW6 operating system with the latest cybersecurity features and updates.

 

You can also find the Ibex-1310-T2G2.5 EUIbex-1310-T2G2.5-PoE EU, and Ibex-1310-T2G2.5-PoE NA models in the WLAN.

 

Easy World Automation offers the easiest way to buy the Westermo Ibex-1310-T2G2.5 NA Industrial Wi-Fi 6 Access Point in the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh), and Oman) at the lowest price through online inquiring. Our sales experts will contact you to fulfill all your industrial automation needs.

Specification

Interfaces
10/100/1000BaseT(X) Ports : 2 x 10/100/1000/2.5G Base-T Ports, 2 x M12 X-coded connectors
Modulation Type -
Frequency Band 2.400 to 2.4835 GHz (2x2 MU-MIMO), 5.150 to 5.350 GHz, 5.470 to 5.725 GHz, 5.725 to 5.875 GHz (2x2 MU-MIMO)
PoE Ports
100BaseFX Ports
Wireless Security WPA2-Personal (CCMP), WPA2-Enterprise, WPA3-Personal (SAE/OWE), WPA3-Enterprise (Suite-B), 802.11w, 802.1X, SecureBoot (TPM), Security Log (persistent)
WLAN Antenna Connector 2 x N-type connector for Wi-Fi 6
Security VPN: SSL Server/Client, IPsec, OpenVPN Client, Wireguard, GRE/GRETAP, VXLAN
WLAN Operation Mode Access Point, Client, Bridge
WLAN Standards IEEE 802.11g, 802.11a, 802.11n, 802.11ac, 802.11ax
1000BaseSFP Slots
Transmission Rates 2.4 GHz: Up to 802.11ax 40 MHz 2SS BW HE11: 573 MBit/s, 5 GHz: Up to 802.11ax 80 MHz 2SS BW HE11: 1201 MBit/s
10/100BaseT(X) Ports
Digital Inputs
Console Port
Serial Ports
M12 Connector
Power Requirement
Input Current -
Connector -
Input Voltage 12 to 48 VDC (Wide Range 9.6 to 60 VDC)
Power Consumption -
Reverse Polarity Protection -
Physical Characteristics
Humidity -
Dimensions Packaged 195 x 70 x 111 mm (7.68 x 2.76 x 4.37 inches)
Weight (PACKAGED) 1.45 kg without antennas
Housing Full metal
Installation -
Standards and Certifications Ingress protection: IP66; Climate: EN 60068-2 [-1, -2, -30], Environmental testing of electronic equipment; EMC: EN 50121-4, Railway applications - Electromagnetic compatibility. Part 4: Emission and immunity of the signalling and telecommunications apparatus, EN/IEC 61000-6-1, Immunity residential environments, EN/IEC 61000-6-2, Immunity industrial environments, EN/IEC 61000-6-3, Emission residential environments, EN/IEC 61000-6-4, Emission industrial environments, ETSI EN 301 489-1, Electromagnetic compatibility (EMC) and Radio spectrum Matters (ERM) for radio equipment and services - Part 1: Common technical requirements, ETSI EN 301 489-17, Electromagnetic compatibility (EMC) and Radio spectrum Matters (ERM) for radio equipment - Part 17: Specific conditions for Broadband Data Transmission Systems; Mechanical (Shock and vibration): EN 50125-3, Outside the track; Radio communication: ETSI EN 300 328, Wideband transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using wide band modulation techniques, ETSI EN 301 893, 5 GHz RLAN, ETSI EN 300 440, 5.8GHz, Short Range Devices, IEEE802.11, Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications, FCC-47-15, Radio frequency devices; Safety: EN/IEC 62368-1, Safety Requirements for audio/video, information and communication technology equipment
Operating Temperature -40 to +70°C (-40 to +158°F)
Storage Temperature -
General
Management SNMP v2c/v3 with USM authentication and encryption support, HTTP/HTTPS web interface and WebAPI with user authentication (local or LDAP), CLI (SSH and Telnet), Certificate Management (SCEP)
LED Indicators : Status
MTBF 400,000 hours
Time Management -