PULS PAS395 DIN-rail Power supply
- Power supply and charger for 400V UltraCaps in one unit
- Rugged flange mount housing with integrated temperature
controlled fan
- Fulfills wind-power industry standards
- Altitudes up to 6000m allowed
- Full output power between -40 and +65°C
- Inhibit input, fully-charged and output-ok relay contacts
Description
- The charger is designed to charge EDLC (electrical double layer capacitors commonly known as Ultracaps, Supercaps or Greencaps) with a constant current – constant voltage characteristic (float charge mode).
- The charger is suitable to be used in a permanently spinning rotor-hub of a wind turbine.
- The charger is suitable for flange mounting. Any mounting orientation is allowed.
- Most of the heat will be conducted through the base-plate of the charger. A good thermal connection to the cabinet or an external heatsink can improve the MTBF and life time expectancy.
- The charger is equipped with an internal fan which turns on when necessary.
- The charger comprises an internal diode in series to the positive output voltage path in order to protect against back-feeding voltages.
- The input-, output and signal terminals are pluggable. Hot-swap ability is not supported.
- A voltage applied on the inhibit terminal stops the charging mode.
- The charger contains a “Fully-Charged” and an “Output-OK” relay contact.
- A redundant control circuit monitors the end-of-charge voltage and switches the charger off in case of a too high voltage. After such an event, automatic start attempts occur until the failure is cleared.
You can place an order for the PULS PAS395 DIN-rail Power supply online via one of our Middle East branches (Dubai/ Oman/Saudi Arabia) and get it delivered at a low cost at a specific time.
Specification
| Input Data | |
|---|---|
| AC-Input Voltage | AC 220-240V (-20%/+10%) |
| DC-Input Voltage | - |
| EN61000-3-2(PFC-Norm) | fulfilled |
| Harmonic Correction | active |
| Power Factor | >0.9 |
| Input Inrush Current Limitation | active |
| Peak turn on current | 14A |
| External Input Fuse Recommendation | min B-10A / C-8A |
| Output Data | |
| nominal Voltage | 410Vdc |
| Adjustment Range | 360-460V |
| Output Current Range | 2.5-2.5A |
| Output Current | 2.5A at 460V, 2.5A at 360V |
| Output Power | 1025W |
| max. Ripple and Noise Voltage | 10mVpp |
| General | |
| Efficency, typ. | 94.4% |
| Power Losses, typ. | 60,8W |
| DC-OK Signal | |
| E Classification | eClass 5.1 27049002, eClass 6.x 27049002, eClass 7.x 27049002, eClass 8.0 27049002, eClass 9.0 27040701, ETIM 4.0 EC000599, ETIM 5.0 EC002540, HS Code HS 85044082 |
| Physical Characteristics | |
| Mounting | DIN-Rail |
| Dimension | 310mm x 158mm x 80mm |
| Weight | 2300g |
| Operating Temperature | -40°C ... +65°C |
| MTBF | - |
| Package Checklist | |
| Packaging Unit | 1pc |