Westermo Viper-002-PL Industrial Ethernet Extender | Easy World Automation

Westermo Viper-002-PL Industrial Ethernet Extender

  • EN 50155 Ethernet Powerline Bridge
  • 1 x 100 Mbps Ethernet port
  • 1 x 2-Wire Cable Port
  • Single model 24 – 110 VDC power range
  • IP67 anti-condensation GORE-TEX® membrane
  • Ambient temperature -40° to +70°C (-40° to +158°F)
  • Integrated M12 threading and high MTBF hours

Description

The Viper-002-PL series consists of Ethernet extenders and bridges for propagating Ethernet traffic over existing cabling. The series is based on power line communication (G.hn) and is capable of bridging high bandwidth Ethernet traffic over 2-wire cables, even when there are oxidized connectors. By simply installing a Viper-002-PL product on each side of the coupler, a bridge connecting the Ethernet networks on each side is created. The power line technology allows using existing cables, which leads to significant financial savings when refurbishing trains. The fact that no configuration is needed further contributes to the ease of use. The Viper-002-PL series has been thoroughly tested by certified labs to ensure its compliance with the standard for electronic equipment used on rolling stock, EN 50155. For several characteristics, Westermo exceeds the requirements mandated by the standard, e.g. by providing 1.5 kVrms insulation on all ports.

Furthermore, the design is based on Westermo’s long experience within the rolling stock market, which brings benefits such as vibration-safe integrated connector threading, IP67 ingress protection with GORE-TEX® membrane to prevent condensation water build-up, and ultimately a high MTBF and long service life under the harshest conditions. The Viper-002-PL series is built in Westermo’s Swedish factory which is renowned for its extremely high standard, as confirmed by many quality audits by demanding international customers. The factory is organized according to lean manufacturing principles and is equipped with sophisticated state-of-the-art quality assurance equipment. Meeting the requirements for rolling stock makes the Viper-002-PL series also very well suited for deployment in other applications with severe operating conditions and extreme environments.


Inquire about the Westermo Viper-002-PL Industrial Ethernet Extender, designed for industrial automation solutions. Feel free to get in touch with our sales team to give you the best solutions at the best global price in the Middle East (UAE (Dubai), KSA (Al Khobar, Riyadh), and Oman).

Specification

Interface
10/100Mb RJ45 (Megabit) Ports : 1 Port
DSL
Serial port
Powerline (B-coded) : 1 Port
Input power (A-coded) : 1 Port
General
Management
Type of ethernet extender Unmanaged
Network working layers Layer 1
Maximum support speed -
Maximum transmission distance -
MTBF 1,285,000 hours
Power Requirements
Power Consumption (Output Adapter) 16.8 to 143 VDC (14.4 VDC for 100 ms, 154 VDC for 1 second), Max at 24 VDC 200 mA, Max at 110 VDC 55 mA
Power Input Plugin ( Redundant ) -
Physical Characteristics
Dimensions 175 x 65 x 100 mm
Standards and Certifications Climate: EN 50155 class OT4 / IEC 60571 class TX, Railway applications - Electronic equipment used on rolling stock, IEEE 1478 class 1, condition E4 (incl Salt Mist), Environmental conditions for transit rail car electronic equipment / EMC: EN/IEC 61000-6-2, Immunity industrial environments, EN/IEC 61000-6-4, Emission industrial environments, EN 50121-4/IEC 62236-4, Railway signalling and telecommunications apparatus, EN 50121-3-2/IEC 62236-3-2, Railway applications – Rolling stock – apparatus, Tested and verified for Class S1, DB EMC Regulation 06, Commodity team Radio compatibility in VDB Rev 1.0 (Shunting Radio), Tested and verified for FCC part 15b class A (CFR 47) / Mechanical (Shock and vibration): EN 61373 category 1, class A and B, EN 60068-2-27 20 g, 11 ms / Insulation (Coordination and test): EN 50124-1, Railway applications – Insulation coordination, EN 50155/IEC 60571, Railway applications - Electronic equipment used on rolling stock / Fire protection: EN 45545-2, Fire protection on railway vehicles / Safety: EN/IEC/UL 62368-1, Safety Requirements for audio/video, information and communication technology equipment
Installation Din-rail
Operating Temperature -40 to +70 °C (-40 to +158°F)
Weight 1.2 kg
Storage temperature -40 to +85 °C (-40 to +185 °F)
Relative Humidity 5 to 95 % relative humidity