Beijer BFI-P2-22-0043-1F4X-TN Frequency inverter
- Output power 0.75 kW
- Output 3x230 VAC, 4.3 A
- Input voltage 1x230 VAC
- IP66
- Brand: BEIJER
- Product Code: BFI-P2-22-0043-1F4X-TN
Description
BFI P2 combines premium control of both standard induction motors and permanent magnet motors with high performance, reliability, and ease of use. Extensive I/O and communications interface capabilities ensure the drive can be integrated quickly and efficiently into a wide variety of control systems and the simple parameter structure with carefully selected factory settings provides fast and easy commissioning.
Discover industrial automation
solutions appropriate to your needs, and easily inquire about the Beijer BFI-P2-22-0043-1F4X-TN Frequency inverter through
our user-friendly website via one of our Middle East branches (UAE (Dubai), KSA
(Al Khobar, Riyadh), and Oman).
Specification
Output ratings | |
---|---|
Output voltage | 3 x 230 VAC |
Rated motor current | 4.3 A |
Overload capacity | 150% for 60 seconds, 200% for 4 seconds |
Output frequency | 0 – 500Hz, 0.1Hz resolution |
Input ratings | |
Supply voltage | 200 – 240VAC ± 10% |
Supply frequency | 48 – 62Hz |
Power cycles | 120 per hour maximum, evenly spaced |
Communication | |
Modbus RTU | 9.6 - 115.2 kbps selectable (8N1, 8N2, 8E1, 8O1) |
BACnet MS/TP | |
Modbus TCP | , the external option |
Ethernet IP | , the external option |
EtherCat | , the external option |
Profinet IO | , the external option |
Profibus DP(DPV1) | , the external option |
Device Net | , the external option |
CC-Link | , the external option |
CAN open | 125-1000 kbps |
Display | |
Programmable display | |
Multi language OLED display | |
External OLED display | |
LED display | |
HVAC | |
PID-control | with sleep/wake up functionality |
Spin start | |
Pump dry protection | |
Stir function | |
Motor pre-heat | |
Broken impeller and broken belt detection | |
Automatic cleaning for pumps | |
Bypass control | |
Fire mode | |
Control terminals | |
Power supply | 100 mA @ 24 VDC, 20 mA @ 10 VDC |
Inputs | 5 in total, 3 Digital, 2 Analog or Digital, selectable |
Digital inputs | 10-30 V DC, PNP, Response time: < 4 msec, Internal or external supply |
Analog inputs | Resolution:12 bit, Response time: <4 msec; Accuracy: <± 2% of full scale, Adjustable scaling |
Relay outputs | Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity: 6A AC, 5A DC |
Analog outputs | 0 to 10 Volt, 0 to 20mA, 4 to 20mA |
Outputs | 4 total, 2 relays, 2 analog or digital |
Standard compliances | |
Conformance | CE, UL |
Marine approvals | |
Earth leakage current | EN 61800-5-1: 2007. Test techniques EN 60990:2000. 1x230 VA < 2,5 mA, 3x400VAC < 4,65 during runing |
Dielectric strength | 61800-5-1: 2007 |
Surge | EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-5:2006. |
Physical Characteristics | |
IP class | IP66 |
Physical size | Size 2 |
Measurements (H x W x D) | 257 mm x 188 mm x 239 mm |
Weight | 4.8 kg |
Built in Main switch, control switch and potentiometer | |
Conformal coated PCBs | |
Operation temperature | -10 to 50 °C |
Humidity | 95% max, non-condensing |