Beijer BFI-H3-24-0041-3F1X-TN Frequency Inverter
- Output power 1.5 kW
- Output 3x400 VAC, 4.1 A
- Input voltage 3x380-480 VAC
- IP66
- Brand: BEIJER
- Product Code: BFI-H3-24-0041-3F1X-TN
Description
BFI H3 includes IP20, IP55, and IP66 inverters for HVAC, maritime, and other industrial applications, and set a new cost-competitive standard for dedicated fan and pump control. Ease-of-use and innovative design combined with robust performance provide powerful flow control and reliability in a compact drive.
You can place an order for the Beijer BFI-H3-24-0041-3F1X-TN Frequency Inverter online via one of our Middle East branches (Dubai/ Oman/Saudi Arabia) and get it delivered at a low cost at a specific time.
Specification
Output ratings | |
---|---|
Output voltage | 3 x 400 VAC |
Rated motor current | 4.1 A |
Overload capacity | 110% for 60 seconds, 125% for 3 seconds |
Output frequency | 0 – 250Hz, 0.1Hz resolution |
Input ratings | |
Supply voltage | 380 – 480VAC ± 10% |
Supply frequency | 48 – 62Hz |
Power cycles | 120 per hour maximum, evenly spaced |
Communication | |
Modbus RTU | 9.6 - 115.2 kbps selectable (8N1, 8N2, 8E1, 8O1) |
Modbus TCP | , the external option |
Ethernet IP | , the external option |
EtherCat | , the external option |
Profinet IO | , the external option |
Profibus DP(DPV1) | , the external option |
Device Net | , the external option |
CC-Link | , the external option |
CAN open | |
Display | |
Programmable display | |
Multi language OLED display | |
External OLED display | |
LED display | |
HVAC | |
PID-control | with sleep/wake up functionality |
Spin start | |
Pump dry protection | |
Stir function | |
Motor pre-heat | |
Broken impeller and broken belt detection | |
Automatic cleaning for pumps | |
Bypass control | |
Fire mode | |
Control terminals | |
Power supply | 100 mA @ 24 VDC, 20 mA @ 10 VDC |
Inputs | 5 in total, 3 Digital, 2 Analog or Digital, selectable |
Digital inputs | 10-30 V DC, PNP, Response time: < 4 msec, Internal or external supply |
Analog inputs | Resolution:12 bit, Response time: <4 msec; Accuracy: <± 2% of full scale, Adjustable scaling |
Relay outputs | Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity: 6A AC, 5A DC |
Analog outputs | 0 to 10 Volt, 0 to 20mA, 4 to 20mA |
Outputs | 4 total, 2 relays, 2 analog or digital |
Standard compliances | |
Conformance | CE, UL |
Marine approvals | |
Earth leakage current | EN 61800-5-1: 2007. Test techniques EN 60990:2000. 1x230 VA < 2,5 mA, 3x400VAC < 4,65 during runing |
Dielectric strength | 61800-5-1: 2007 |
Surge | EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-5:2006. |
Physical Characteristics | |
IP class | IP66 |
Physical size | Size 2 |
Measurements (H x W x D) | 257 mm x 188 mm x 260 mm |
Weight | 5.5 kg |
Built in Main switch, control switch and potentiometer | |
Conformal coated PCBs | |
Operation temperature | -10 to 40 °C |
Humidity | 95% max, non-condensing |